Special versions | Additional identification code -Z with order code and plain text if required | |
---|---|---|
Motor protection | ||
Motor protection with PTC thermistors with 1 (for motors 1LE10 FS 80 and 90) or 3 embedded temperature sensors for tripping | A11 | |
Motor protection with PTC thermistors with 6 embedded temperature sensors for alarm and tripping | A12 | |
Motor temperature detection with embedded temperature sensor KTY 84-130 | A23 | |
Motor temperature detection with embedded temperature sensors 2 x KTY 84‑130 | A25 | |
Temperature detectors for tripping | A31 | |
Installation of 3 PT100 resistance thermometers | A60 | |
Installation of 6 PT100 resistance thermometers in stator winding | A61 | |
Installation of 2 PT100 screw-in resistance thermometers in basic circuit for rolling-contact bearings | A72 | |
Installation of 2 PT100 screw-in resistance thermometers in 3-wire circuit for rolling-contact bearings | A78 | |
Installation of 2 PT100 double screw-in resistance thermometers in 3-wire circuit for rollingcontact bearings | A80 | |
Motor connection and connection box | ||
Two-part plate on connection box | K06 | |
Undrilled entry plate | L01 | |
Connection box on RHS | K09 | |
Connection box on LHS | K10 | |
Connection box on top, feet screwed on | K11 | |
Connection box in cast-iron version | K15 | |
One metal cable gland | K54 | |
Cable gland, max. configuration | K55 | |
Rotation of the connection box through 90°, entry from DE | K83 | |
Rotation of the connection box through 90°, entry from NDE | K84 | |
Rotation of the connection box through 180° | K85 | |
Next larger connection box | L00 | |
External grounding | L13 | |
6 cables protruding, 1.5 m long | L48 | |
6 cables protruding, 3 m long | L49 | |
Protruding cable ends – right side | L51 | |
Protruding cable ends – left side | L52 | |
Auxiliary connection box 1XB3020 | L97 | |
Stud terminal for cable connection, accessories pack | M46 | |
Saddle terminal for connection without cable lug, accessories pack | M47 | |
Windings and insulation | ||
Temperature class 155 (F), used acc. to 155 (F), with service factor (SF) | C11 | |
Temperature class 155 (F), used acc. to 155 (F), with increased output | C12 | |
Temperature class 155 (F), used acc. to 155 (F), with increased coolant temperature | C13 | |
Temperature class 180 (H) at rated output and max. CT 60 °C | C18 | |
Increased air humidity/temperature with 30 to 60 g water per m3 of air | C19 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 45 °C, derating approx. 4 % | C22 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 50 °C, derating approx. 8 % | C23 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 55 °C, derating approx. 13 % | C24 | |
Temperature class 155 (F), used acc. to 130 (B), coolant temperature 60 °C, derating approx. 18 % | C25 | |
Increased air humidity/temperature with 60 to 100 g water per m3 of air | C26 | |
Temperature class 155 (F), used acc. to 130 (B), with higher coolant temperature and/or site altitude | Y50 • and specified output, CT .. °C or SA …. m above sea level | |
Temperature class 155 (F), used acc. to 155 (F), other requirements | Y52 • and specified output, CT .. °C or SA …. m above sea level | |
Colors and paint finish | ||
Standard finish in RAL 7030 stone gray | – | |
Special finishin RAL 7030 gray | K26 | |
Special finish in other standard RAL colors | Y54 • and special finish RAL …. | |
Special finish in special RAL colors | Y51 • and special finish RAL …. | |
Special finish for use offshore | M91 | |
Special finish sea air resistant | M94 | |
Unpainted (only cast-iron parts primed) | K23 | |
Unpainted, only primed | K24 | |
Modular technology – Basic versions | ||
Mounting of separately driven fan | G17 | |
Mounting of brake | G26 | |
Mounting of 1XP8001-1 (HTL) rotary pulse encoder | H57 | |
Mounting of 1XP8001-2 (TTL) rotary pulse encoder | H58 | |
Modular technology – Combinations of basic versions | ||
Mounting of separately driven fan and 1XP8001-1 rotary pulse encoder | H61 | |
Mounting of brake and 1XP8001-1 rotary pulse encoder | H62 | |
Mounting of brake and separately driven fan | H63 | |
Mounting of brake, separately driven fan and 1XP8001-1 rotary pulse encoder | H64 | |
Mounting of separately driven fan and 1XP8001-2 rotary pulse encoder | H97 | |
Mounting of brake and 1XP8001-2 rotary pulse encoder | H98 | |
Mounting of brake, separately driven fan and 1XP8001-2 rotary pulse encoder | H99 | |
Modular technology – Additional versions | ||
Brake supply voltage 24 V DC | C00 | |
Brake supply voltage 400 V AC | C01 | |
Mechanical manual brake release with lever (no locking) | K82 | |
Special technology | ||
Mounting of LL 861 900 220 rotary pulse encoder | H70 | |
Mounting of HOG 9 D 1024 I rotary pulse encoder | H72 | |
Mounting of HOG 10 D 1024 I rotary pulse encoder | H73 | |
Prepared for mounting of LL 861 900 220 | H78 | |
Prepared for mounting of HOG 9 D 1024 I | H79 | |
Prepared for mounting of HOG 10 D 1024 I | H80 | |
Mounting of HOG 10 DN 1024 I rotary pulse encoder, terminal box protection against humidity | J15 | |
Mounting of HOG 10 DN 1024 I rotary pulse encoder, terminal box protection against dust | J16 | |
Mounting of HOG 10 DN 1024 I rotary pulse encoder + centrifugal switch, (speed .... rpm), terminal box protection against humidity | Y74 • and required speed .... rpm | |
Mounting of HOG 10 DN 1024 I rotary pulse encoder + centrifugal switch, (speed .... rpm), terminal box protection against dust | Y76 • and required speed .... rpm | |
Mounting of HOG 10 DN 1024 I rotary pulse encoder + ESL 93, (speed .... rpm), terminal box protection against dust | Y79 • and required speed (max 3) .... rpm | |
Mechanical design and degrees of protection | ||
Drive-end seal for flangemounting motors, oil-tight to 0.1 bar | K17 | |
Low-noise version for 2-pole motors with clockwise direction of rotation | K37 | |
Low-noise version for 2-pole motors with counterclockwise direction of rotation | K38 | |
IP65 degree of protection | K50 | |
IP56 degree of protection | K52 | |
Vibration-proof version | L03 | |
Condensation drainage holes | L12 | |
Rust-resistant screws (externally) | M27 | |
Grounding brush for converter-fed operation | M44 | |
Mechanical protection for encoder | M68 | |
Coolant temperature and site altitude | ||
Coolant temperature –50 to +40 °C | D02 | |
Coolant temperature –40 to +40 °C | D03 | |
Coolant temperature –30 to +40 °C | D04 | |
Designs in accordance with standards and specifications | ||
IE1 motor without CE marking for export outside EEA (see EU Directive 640/2009) | D22 | New! |
Premium Efficiency IE3 | D25 | |
Electrical according to NEMA MG1-12 | D30 | |
Design according to UL with "Recognition Mark | D31 | |
Certified for Korea acc. to KS C4202 | D33 | |
China Energy Efficiency Label | D34 | New! |
Canadian regulations (CSA) | D40 | |
NEMA Premium Efficient, North America version according to NEMA MG1, Table 12-12, incl. UL and CSA | D41 | New! |
NEMA Energy Efficient, North America version according to NEMA MG1, Table 12-11, incl. UL and CSA | D42 | New! |
PSE mark for Japan | D46 | |
VIK version | K30 | |
Ex nA II on VIK rating plate | C27 | |
Bearings and lubrication | ||
Measuring nipple for SPM shock pulse measurement for bearing inspection | G50 | |
Bearing design for increased cantilever forces | K20 | |
Special bearing for DE and NDE, bearing size 63 | K36 | |
Regreasing device | K40 | |
Located bearing DE | K94 | |
Located bearing NDE | L04 | |
Insulated bearing cartridge | L27 | |
Balance and vibration quantity | ||
Vibration quantity level A | – | |
Vibration quantity level B | K02 | |
Full-key balancing | L68 | |
Balancing without key | M37 | |
Shaft and rotor | ||
Concentricity of shaft extension, coaxiality and linear movement in accordance with DIN 42955 Tolerance R for flange-mounting motors | K04 | |
Second standard shaft extension | K16 | |
Shaft extension with standard dimensions, without feather keyway | K42 | |
Concentricity of shaft extension in accordance with DIN 42955 Tolerance R | L39 | |
Standard shaft made of stainless steel | M65 | |
Non-standard cylindrical shaft extension | Y55 • and identification code | |
Heating and ventilation | ||
Fan cover for textile industry | H17 | |
Metal external fan | K35 | |
Anti-condensation heating for 230 V | K45 | |
Anti-condensation heating for 115 V | K46 | |
Sheet metal fan cover | L36 | |
Separately driven fan with non-standard voltage and/orfrequency | Y81 • and identification code | |
Rating plate and extra rating plates | ||
Second lubrication plate, loose | B06 | |
Extra rating plate for voltage tolerance | B07 | New! |
Second rating plate, loose | K31 | |
Rating plate, stainless steel | M40 | New! |
Extra rating plate or rating plate with deviating rating plate data | Y80 • and identification code | |
Extra rating plate with identification codes | Y82 • and identification code | |
Additional information on rating plate and on package label (max. 20 characters) | Y84 • and identification code | |
Packaging, safety notes, documentation and test certificates | ||
With one safety and start-up guide per box pallet | B01 | |
Acceptance test certificate 3.1 in acc. with EN 10204 | B02 | |
Printed German/English Operating Instructions (Compact) enclosed | – | |
Printed German/English Operating Instructions enclosed | B23 | |
Type test with heat run for horizontal motors, with acceptance | F83 | |
Wire-lattice pallet | L99 | |
Connected in star for dispatch | M32 | |
Connected in delta for dispatch | M33 |
The components of modular technology can be ordered as accessories. The brake, as a safety-related module, must not be retrofitted.
Cables for rotary pulse encoders can be ordered from Catalog DA 65.10.
Mounting of rotary pulse encoder and separately driven fan for 1LA5, 1LA6, 1LA7 and 1LG motors | Weight | ||||
---|---|---|---|---|---|
Version | Frame size | Number of poles | Order No. | kg | |
Rotary pulse encoder 1) | HTL version | 100 ... 225 | All | 1XP8 001-1 | 0.3 |
TTL version | 100 ... 225 | All | 1XP8 001-2 | 0.3 | |
Separately driven fan | 100 | All | 2CW2180-8RF54-1AB0 | 3.9 | |
112 | All | 2CW2210-8RF54-1AB1 | 4.4 | ||
132 | All | 2CW2250-8RF54-1AB2 | 6.7 | ||
160 | All | 2CW2300-8RF54-1AB3 | 7.2 | ||
180 | All | 2CW2300-8RF54-1AB4 | 9.8 | ||
200 | All | 2CW2300-8RF54-1AB5 | 10.7 | ||
225 3) | All | 2CW2300-8RF54-1AB6 | 10.7 | ||
250 | All | 1PP9063-2LA12-ZA11+K50 4) | On request | ||
280 | All | 1PP9063-2LA12-ZA11+K50 4) | On request | ||
315 | 2 | 1PP9070-2LA12-ZA11+K50 4) | On request | ||
315 | 4 to 8 | 1PP9063-2LA12-ZA11+K50 4) | On request | ||
Separately driven fan and rotary pulse encoder 1XP8001-1 | 100 | All | 2CW2180-8RF54-2AB0 | 4.2 | |
112 | All | 2CW2210-8RF54-2AB1 | 4.7 | ||
132 | All | 2CW2250-8RF54-2AB2 | 6.0 | ||
160 | All | 2CW2300-8RF54-2AB3 | 7.5 | ||
180 | All | 2CW2300-8RF54-2AB4 | 10.1 | ||
200 | All | 2CW2300-8RF54-2AB5 | 11.0 | ||
225 3) | All | 2CW2300-8RF54-2AB6 | 11.0 |
1) For motor series 1LG, the rotary pulse encoders are available on request. They are only available for motor series 1LA7 as accessories for spare parts.
2) The separately driven fan 2CW2 ... comprises a complete fan unit with impeller, the separately driven fan 1PP9 ... only comprises the fan motor without mounting components and impeller.
3) For 1LG motors with separately driven fan with Order No. 1PP9 063-2LA12-Z A11+K50 (weight 4.37 kg).
4) Only for replacement purposes.
In the case of mounting by the customer.
Options H79, H80
Baumer Hübner GmbH
Postfach 126943
10609 Berlin, Germany
Tel. +49 (0) 30-690 03-0
Fax +49 (0) 30-690 03-104
http://www.baumerhuebner.com
E-mail: info@baumerhuebner.com
Option H78
Leine & Linde (Deutschland) GmbH
Bahnhofstraße 36
73430 Aalen, Germany
Tel. +49 (0) 7361-78 093-0
Fax +49 (0) 7361-78 093-11
http://www.leinelinde.com
E-mail: info@leinelinde.se
Slide rails are used to tension the belt of a machine easily and conveniently when a belt tightener is not available. They are fixed to the base using stone bolts or foundation blocks.
The assignment of slide rails to motor size can be found in DIN 42923. For motors of frame sizes 355 to 450, there are no standardized slide rails (please inquire).
Source of supply:
Lütgert & Co. GmbH
Postfach 42 51
33276 Gütersloh, Germany
Tel. +49 (0)5241-74 07-0
Fax +49 (0)5241-74 07-90
http://www.luetgert-antriebe.de
E-mail: info@luetgert-antriebe.de
The foundation blocks are inserted into the stone foundation and embedded in concrete. They are used for fixing machines of medium size, slide rails, pedestal bearings, baseframes, etc. After the fixing bolts have been unscrewed, the machine can be dragged without it having to be lifted.
When the machine is initially installed, the foundation block that is bolted to the machine (without washers) and fitted with tapered pins is not embedded with concrete until the machine has been fully aligned. The machine is set 2 to 3 mm deeper in this case. The difference in shaft height is compensated by inserting shims on final installation. The tapered pins safeguard the exact position of the machine when it is repeatedly removed and replaced without the need for realignment.
Source of supply:
Lütgert & Co. GmbH
Postfach 42 51
33276 Gütersloh, Germany
Tel. +49 (0)5241-74 07-0
Fax +49 (0)5241-74 07-90
http://www.luetgert-antriebe.de
E-mail: info@luetgert-antriebe.de
Taper pins are used for components that are repeatedly removed. The drilled hole is ground conical using a conical reamer until the pin can be pushed in by hand until the cone shoulder lies approx. 3 to 4 mm above the rim of the hole.
It can then be driven in using a hammer until it is correctly seated. The pin is removed from the drilled hole by screwing on the nut and tightening it.
Standardized taper pins are available from general engineering suppliers.
Source of supply, for example:
Otto Roth GmbH & Co. KG
Rutesheimer Straße 22
70499 Stuttgart, Germany
Tel. +49 (0)711-13 88-0
Fax. +49 (0)711-13 88-233
http://www.ottoroth.de
E-mail: info@ottoroth.de
The motor from Siemens is connected to the machine or gear unit through a coupling. Siemens is an important coupling manufacturer with a wide range of products.
For standard applications, Siemens recommends that elastic couplings of types N-EUPEX and RUPEX or torsionally rigid couplings of types ARPEX and ZAPEX are used. For special applications, FLUDEX and ELPEX-S couplings are recommended.
Source of supply:
Siemens contact partner - ordering from Catalog Siemens MD 10.1 "FLENDER Standard Couplings"
or
SIEMENS AG
Kupplungswerk Mussum
Industriepark Bocholt
Schlavenhorst 100
46395 Bocholt, Germany
Tel. +49 (0)2871-92 21 85
Fax +49 (0)2871-92 25 79
Example for ordering a fan cover 1LA7,
frame size 160 L, 6-pole:
Fan cover No. 7.40,
1LA7 166-6AA60-Z, factory No. E0912/5229221_01_001
You will find telephone numbers for other countries on our Internet site:
http://www.siemens.com/automation/service&support