Область применения

  • Hoisting, slewing, luffing, trolley and long travel gears as well as single and multi-motor drives
  • The devices are ideally suited to crane modernization applications, because the existing components such as motors, resistors, cables, etc. can usually be reused.
  • Devices are available in special versions for high ambient temperatures up to 65 °C.

Обзор

The SIMOTRAS HD AC power controller is used for the open and closed-loop control of three-phase slip-ring rotor motors for cranes and hoisting gear.

SIMOTRAS HD is a fully-controlled digital, 3-phase thyristor controller in a compact design with stator phase control and electronic field reversal with ratings of between 20 and 580 kW for the open and closed-loop control of slip-ring rotor motors for cranes and hoisting gear.

All converters are equipped with a basic PMU operator panel in the door of the unit. The PMU can be used to perform all the adaptations, settings and measured value displays required for commissioning. The basic unit can also be operated via its serial service interface using a commercially available PC and suitable software. All device settings (e.g. controller parameters, limits, etc.) are stored in the device in a non-volatile memory.

Дизайн

The SIMOTRAS HD device comprises:

  • The power unit
  • Basic electronics
Power unit

The power unit is a 3-phase thyristor AC power controller in a compact design. Two additional thyristor modules in the lateral branch of the power unit enable reversing of the rotating field, and therefore 4Q operation of the drive. Current transformers in 2 phases generate the actual current value for current control.

Basic electronics

The basic electronics contains the gating unit that activates the thyristors. It generates line-synchronized firing pulses. The control electronics is isolated from the line potential via firing pulse transformers.

All device settings (e.g. controller parameters, limits, etc.) are stored in the device in a non-volatile memory. Adjustment is performed digitally, via the operator panel on the device. The values are therefore easy to reproduce at any time.

Depending on the load conditions, the converter operates in motor mode (driving direction of rotating field, 1st and 3rd quadrant) or in braking mode with reversing current braking (2nd and 4th quadrant). Through omission of the conventional stator contactors, fast torque reversal is possible, with resulting high control dynamics.

Supplementary modules

See the section Electronics options section.

Характеристика

The speed changes steplessly in the control range when the master switch is operated. The crane driver only detects the end of the control range through latching of the master switch. Furthermore, the final stage is reached sub-synchronously or super-synchronously, depending on the load, by traversing the characteristics that are determined by the resistor increments. Current control is always operating to ensure that the set maximum torques are not exceeded. It goes without saying that the circuits are protected against reversal.

Control characteristics for hoists

Up to 4 rotor resistor switching stages can be provided. If less than 4 stages are implemented, the top stages (S3/S4) remain unused.

If the upper stages S3/S4 are not used, the over-synchronized speed increases in accordance with the parameterized characteristic on lowering. This must be taken into account when selecting overspeed protection. For this reason, a speed corresponding to the characteristic can also only be achieved during lifting.

Control characteristics for gantries

Up to 4 rotor resistor switching stages can be provided. If less than 4 stages are implemented, the top stages (S3/S4) remain unused.

Функции

Master switch signals

The incoming signals from the master switch, such as setpoint and control enable, are loaded.

  • A master switch with setpoint potentiometer can be connected direct to the SIMOTRAS HD.
  • A 4‑stage master switch requires the CUD2 terminal expansion module for connection.
Ramp-function generator

The series-connected ramp-function generator with adjustable ramps forms the speed setpoint.

Speed controller

The speed controller with the subordinate current control circuit is connected down-circuit of the ramp-function generator and forms the actual control loop.

Start pulse

A start pulse is also generated so that the machine is activated in the hoisting direction of rotation immediately after power up. This prevents the load from dropping on start-up.

Sequencer

For switching through the rotor stages, a sequencer is installed that selects the planned stages speed-dependently and activates reversing.

Standstill monitoring

The integral zero-speed monitoring supports guided, electrical braking of the drive. For replacing the cable, e.g. in hoists, jog mode with creep speed is provided.

Operating states

The operating states are indicated in the device on a 5-digit, 7-segment display as well as the LEDs of the basic PMU operator panel.

Operating modes

The threshold for switchover between closed-loop and open-loop controlled operation can be defined in accordance with the control characteristic and set on the parameters of the device.

Parallel connection

To increase the performance, up to 6 devices can be connected in parallel. The terminal expansion option (CUD2) is required in this case for every device and (n-1) patch cable. Current splitting requires identical, separate parallel switching reactors for each SIMOTRAS device. The difference in reactor tolerances determines the current distribution. For operation without derating (current reduction), a tolerance of 5 % or better is recommended. Only devices with the same current ratings are permitted to be connected in parallel.

Интеграция

Crane technology

The drive-based (crane) control is integrated into the SIMOTRAS HD device. The SIMOTRAS HD device comprises:

  • Power unit
  • Electronics box with basic electronics

The drive-based (crane) control is designed to permit easy switchover between master switches with setpoint potentiometers and 4-stage master switches: The control functions can be specified by terminals.

Конфигурация

Notes on configuration

Rated current of the device Irated

In crane operation, the motors are not operated continuously, but with variable load, at varying speeds, and with different ON durations. Under these conditions, it is sufficient when the rated current for the device Irated is greater than the motor rated current. In intermittent duty with appropriate pauses in operation, the devices can carry twice the rated device current of Irated greater than the rated motor current for 20 s. In intermittent duty with appropriate pauses in operation, the devices can carry twice the rated device current of Irated for 20 s. This covers all the normal acceleration situations that occur with cranes. The SIMOTRAS HD devices can be operated continuously at the rated current for the device Irated; the limit temperature for the thyristors will, however, be reached. Acceleration is not permitted from this operating state since the thyristors could be overloaded.

Rotor contactors

To ensure a reliable ramp-up from the closed-loop control characteristic to rated speed, it is recommended that 4 rotor contactors are used. Activation of the rotor contactors through contactor relays.

Permissible ON duration

Under unusual operating conditions, such as traversing with full load at extremely low speed for a long time, motors, resistors and SIMOTRAS HD must be dimensioned appropriately. When phase angle control is used, a higher stator current flows to achieve the necessary torque due to the reduced magnetization. The motors may become thermally overloaded, because the thermal power losses rise with the quadrant of the current. The resistors are overloaded when the closed-loop control characteristic is traversed for an extended period.

Rotor resistances

Since the speed is influenced with additional rotor resistors, the rotor performance is largely converted into heat in the external resistor. This ensures that excessive heating of the motor is avoided when traversing at low speed over long periods.

Emergency or safety limit switch

Due to the lack of stator contactors, the motor can no longer be galvanically isolated from the AC power controller, e.g. when an operational limit switch is actuated. If the controller is then not able to block the thyristors due to a device fault, this could result in an impermissible operating state.
It is therefore recommended that emergency or safety limit switches are used. These respond when the operational limit switch is passed and act on a line contactor or the crane switch.

Чертеж

D400/60‑180 Mre device type

1) Minimum clearance for air circulation. An adequate flow of cooling air must be provided.

D400/225‑360 Mre device type

1) Minimum clearance for air circulation. An adequate flow of cooling air must be provided.

D400/525 Mre device type

1) Minimum clearance for air circulation. An adequate flow of cooling air must be provided.

D400/680 Mre device type

1) Minimum clearance for air circulation. An adequate flow of cooling air must be provided.

D400/900 Mre device type

1) Minimum clearance for air circulation, customer connection and fan replacement. An adequate flow of cooling air must be ensured.

2) Remove transport plate before commissioning by removing 6 M6 hexagon bolts.

Особенности

  • Compact design
    with the open-loop control integrated in the drive
  • Favorably-priced solution in the retrofit area
    by using slip-ring rotor motors that already exist in the plant or system

Опции

The SIMOTRAS HD converters can be ordered with the following options:

Description

Article No.

Order code

Operation of the SIMOTRAS HD devices at +65 °C ambient temperature

 

H78

SIMOTRAS HD Operating Instructions

In printed form

Languages: English

6SG7000-0BA76

D76

SIMOTRAS HD Operating Instructions and DriveMonitor commissioning tool

On CD-ROM

Languages: English, German

6SG7000-0CD00

D64



Operating Instructions in German are supplied with every device.

Технические данные

AC power controller in the basic version

Product designation

SIMOTRAS HD AC power controller

Type

6SG7050-0EB60-0

6SG7052-0EB60-0

6SG7055-0EB60-0

6SG7060-0EB60-0

6SG7062-0EB60-0

6SG7065-0EB60-0

110 ... 500 V 3 AC, 60 ... 180 A

Rated supply voltage

Power unit

V

110 -10 % ... 500 + 10 % 3 AC

Rated frequency

Hz

50/60

The devices automatically adjust to the frequency of the applied line
voltage in a range from 45 ... 65 Hz.

Rated current

A

60

78

98

112

142

180

Rated supply voltage

Electronic power supply

V

380 (-25 %) ... 460 (+15 %) 2 AC Irated = 1 A
or 190 (25 %) ... 230 (+15 %) 1 AC Irated = 2 A
(-35 % for 1 min.)

Phase fuse1)

3 units

A/V

3NE1820-0
80/690

3NE1021-0
100/690

3NE10220-0
125/690

3NE1024-0
160/690

3NE1224-0
160/690

3NE1225-0
200/690

Rated supply voltage

Fan

V

24 DC internal

Overload possibility2)

 

20 s duration: I = 2 × Irated
then 70 s duration: I = Irated
then 60 s duration: I = 0 A
(cycle duration 150 s)

Power loss for rated current, approx.

W

272

306

386

439

500

630

Minimum load

A

3

6

6

6

7

7

Ambient temperature during operation at rated current

°C

0 ... 45
self-ventilation

0 ... 40
forced ventilation

Upper limit temperature with current derating

°C

55

50

Cooling air requirement

m3/h

100

Sound pressure level LpA (1 m)

dB

40

Storage and transport temperature

°C

-25 ... +70

Installation altitude above sea level

m

≤ 1000 at rated current
max. 3500 with reduced voltage and current

Environmental class
DIN IEC 60721‑3‑3

 

3K3

Degree of protection
DIN EN 60529

 

IP00

IP00

IP00

IP00

IP00

IP00

D400 device type

 

60 Mre

78 Mre

98 Mre

112 Mre

142 Mre

180 Mre

Dimensions

 

See dimensional drawings

Weight, approx.

kg

16

16

16

16

17

17



1) The fuses listed are not included with the device. The fuses listed are recommended fuses that must be ordered separately.

2) It is permissible to operate the device without interruption with the rated connection current Irated. This will cause the thyristors to reach their limit temperature. It is not possible to accelerate, i.e. increase the current from this operating state.

Product designation

SIMOTRAS HD AC power controller

Type

6SG7070-0EB60-0

6SG7072-0EB60-0

6SG7076-0EB60-0

6SG7080-0EB60-0

6SG7082-0EB60-0

6SG7085-0EB60-0

110 ... 500 V 3 AC, 225 ... 900 A

Rated supply voltage

Power unit

V

110 -10 % ... 500 + 10 % 3 AC

Rated frequency

Hz

50/60

The devices automatically adjust to the frequency of the applied line
voltage in a range from 45 ... 65 Hz.

Rated current

A

225

285

360

525

680

900

Rated supply voltage

Electronic power supply

V

380 (-25 %) ... 460 (+15 %) 2 AC Irated = 1 A
or 190 (-25 %) ... 230 (+15 %) 1 AC Irated = 2 A
(-35 % for 1 min.)

Phase fuse1)

3 units

A/V

3NE1227-0
250/690

3NE1331-0
350/690

3NE1332-0
400/690

3NE1435-0
560/690

3NE3340-8
900/690

6RY1702-0BA012) '
1250/660

Rated supply voltage

Fan

V

400 (± 15 %) 3 AC 50 Hz
460 (± 10 %) 3 AC 60 Hz

400 (± 10 %) 3 AC 50 Hz
460 (± 10 %) 3 AC 60 Hz

Rated current

Fan

A

0.24

1.1

Overload possibility3)

 

20 s duration: I = 2 × Irated
then 70 s duration: I = Irated
then 60 s duration: I = 0 A
(cycle duration 150 s)

Power loss for rated current, approx.

W

839

1020

1300

1827

2890

3550

Minimum load

A

10

10

10

15

15

15

Ambient temperature during operation at rated current

°C

0 ... 40
forced ventilation

Upper limit temperature with current derating

°C

50

Cooling air requirement

m3/h

570

1400

2400

Sound pressure level LpA (1 m)

dB

73

88

Storage and transport temperature

°C

-25 ... +70

Installation altitude above sea level

m

≤ 1000 at rated current
max. 3500 with reduced voltage and current

Environmental class
DIN IEC 60721‑3‑3

 

3K3

Degree of protection
DIN EN 60529

 

IP00

IP00

IP00

IP00

IP00

IP00

D400 device type

 

225 Mre

285 Mre

360 Mre

525 Mre

680 Mre

900 Mre

Dimensions

 

See dimension drawings

Weight, approx.

kg

30

30

30

45

85

137



1) The fuses listed are not included with the device. The fuses listed are recommended fuses that must be ordered separately.

2) Fuses included with device. No semiconductor fuses are necessary.

3) It is permissible to operate the device without interruption with the rated connection current Irated. This will cause the thyristors to reach their limit temperature. It is not possible to accelerate, i.e. increase the current from this operating state.

AC power controller in the special version

Product designation

SIMOTRAS HD AC power controller

Type

6SG7050-0EB60-0-Z
H78

6SG7052-0EB60-0-Z
H78

6SG7055-0EB60-0-Z
H78

6SG7060-0EB60-0-Z
H78

6SG7062-0EB60-0-Z
H78

6SG7065-0EB60-0-Z
H78

110 ... 500 V 3 AC, 42 ... 125 A, ambient temperature ​65 °C (option H78)

Rated supply voltage

Power unit

V

110 -10 % ... 500 + 10 % 3 AC

Rated frequency

Hz

50/60

The devices automatically adjust to the frequency of the applied line
voltage in a range from 45 ... 65 Hz.

Rated current

A

42

55

70

80

100

125

Rated supply voltage

Electronic power supply

V

380 (-25 %) ... 460 (+15 %) 2 AC Irated = 1 A
or 190 (-25 %) ... 230 (+15 %) 1 AC Irated = 2 A
(-35 % for 1 min.)

Phase fuse1)

3 units

A/V

3NE1820-0
80/690

3NE1021-0
100/690

3NE10220-0
125/690

3NE1024-0
160/690

3NE1224-0
160/690

3NE1225-0
200/690

Rated supply voltage

Fan

V

24 DC internal

Overload possibility2)

 

20 s duration: I = 2 × Irated
then 70 s duration: I = Irated
then 60 s duration: I = 0 A
(cycle duration 150 s)

Power loss for rated current, approx.

W

205

230

288

322

365

445

Minimum load

A

3

6

6

6

7

7

Ambient temperature during operation at rated current

°C

0 ... 65

Cooling air requirement

m3/h

100

Sound pressure level LpA (1 m)

dB

40

Storage and transport temperature

°C

-25 ... +70

Installation altitude above sea level

m

≤ 1000 at rated current
max. 3500 with reduced voltage and current

Environmental class
DIN IEC 60721‑3‑3

 

3K3

Degree of protection
DIN EN 60529

 

IP00

IP00

IP00

IP00

IP00

IP00

D400 device type

 

60 Mre

78 Mre

98 Mre

112 Mre

142 Mre

180 Mre

Dimensions

 

See dimension drawings

Weight, approx.

kg

16

16

16

16

17

17



1) The fuses listed are not included with the device. The fuses listed are recommended fuses that must be ordered separately.

2) It is permissible to operate the device without interruption with the rated connection current Irated. This will cause the thyristors to reach their limit temperature. It is not possible to accelerate, i.e. increase the current from this operating state.

Product designation

SIMOTRAS HD AC power controller

Type

6SG7070-0EB60-0-Z
H78

6SG7072-0EB60-0-Z
H78

6SG7076-0EB60-0-Z
H78

6SG7080-0EB60-0-Z
H78

6SG7082-0EB60-0-Z
H78

6SG7085-0EB60-0-Z
H78

110 ... 500 V 3 AC, 150 ... 700 A, ambient temperature· 65 °C (option H78)

Rated supply voltage

Power unit

V

110 -10 % ... 500 + 10 % 3 AC

Rated frequency

Hz

50/60

The devices automatically adjust to the frequency of the applied line
voltage in a range from 45 ... 65 Hz.

Rated current

A

150

200

250

365

475

700

Rated supply voltage

Electronic power supply

V

380 (-25 %) ... 460 (+15 %) 2 AC Irated = 1 A
or 190 (-25 %) ... 230 (+15 %) 1 AC Irated = 2 A
(-35 % for 1 min.)

Phase fuse1)

3 units

A/V

3NE1227-0
250/690

3NE1331-0
350/690

3NE1332-0
400/690

3NE1435-0
560/690

3NE3340-8
900/690

6RY1702-0BA012)
1250/660

Rated supply voltage

Fan

V

400 (± 15 %) 3 AC 50 Hz
460 (± 10 %) 3 AC 60 Hz

400 (± 10 %) 3 AC 50 Hz
460 (± 10 %) 3 AC 60 Hz

Rated current

Fan

A

0.24

1.1

Overload possibility3)

 

20 s duration: I = 2 × Irated
then 70 s duration: I = Irated
then 60 s duration: I = 0 A
(cycle duration 150 s)

Power loss for rated current, approx.

W

595

731

895

1280

2146

2865

Minimum load

A

10

10

10

15

15

15

Ambient temperature during operation at rated current

°C

0 ... 65

Cooling air requirement

m3/h

570

1400

2400

Sound pressure level LpA (1 m)

dB

73

88

Storage and transport temperature

°C

-25 ... +70

Installation altitude above sea level

m

≤ 1000 at rated current
max. 3500 with reduced voltage and current

Environmental class
DIN IEC 60721‑3‑3

 

3K3

Degree of protection
DIN EN 60529

 

IP00

IP00

IP00

IP00

IP00

IP00

D400 device type

 

225 Mre

285 Mre

360 Mre

525 Mre

680 Mre

900 Mre

Dimensions

 

See dimension drawings

Weight, approx.

kg

30

30

30

45

85

137



1) The fuses listed are not included with the device. The fuses listed are recommended fuses that must be ordered separately.

2) Fuses included with device. No semiconductor fuses are necessary.

3) It is permissible to operate the device without interruption with the rated connection current Irated. This will cause the thyristors to reach their limit temperature. It is not possible to accelerate, i.e. increase the current from this operating state.

Option H78:

Operation at an ambient temperature higher than +65 °C is not possible. The rated current, reduced compared to the standard version, must be maintained across the entire temperature range of 0 ... 65 °C.

Load values depending on the temperature of the coolant and installation altitude

Ambient or coolant temperature

Change in load values

 

Basic version

Special version (option H78)

 

Devices with self-ventilation

Devices with forced ventilation

Devices with self-ventilation

Devices with forced ventilation

+35 °C

0%

0%

0%

0%

+40 °C

0%

0%

0%

0%

+45 °C

0%

-5 %

0%

0%

+50° C

-6 %

-10 %

0%

0%

+55 °C

-12 %

Not permissible

0%

0%

+60 °C

Not permissible

Not permissible

0%

0%

+65 °C

Not permissible

Not permissible

0%

0%



Reduction factor for load values at installation altitudes above 1000 m

Дальнейшая информация

Reference to SIMOTRAS HE

SIMOTRAS HD is almost fully compatible with SIMOTRAS HE (6GA4625... series).

 

SIMOTRAS HD

SIMOTRAS HE

Type

6SG70....-.....-0

6GA4625..-.....-.

Circuitry

Digital

Analog

Voltage range

110 ... 500 V 3 AC ±10 %

110 ... 500 V 3 AC ±10 %

Current range

42 ... 900 A

27 ... 1125 A

Isolated binary signals

8 inputs and 8 outputs

7 inputs and 8 outputs

Drive-related control available?

Yes

No

Do rotor contactors switch at zero current?

Yes

No

Are the devices interchangeable?

HE can be replaced with HD easily, taking the installation conditions into account.

External activation of the HE must be adapted to the internal drive-based control of the HD!

HD can only be replaced with HE after careful inspection, possibly by external service providers.

Additional equipment is necessary.

Check the installation conditions!

Are the pulse generator evaluation, setpoint encoder, etc. standard?

Yes

No

Are freely connectable terminals and spare function blocks available for calculation and closed-loop control as well as for logic operations?

Yes

No

Is binary and analog terminal expansion possible?

Yes, via status display

No

CE marking present?

Yes

Yes



preloader

58181