preloader
mail@uselogic.ru  +7(495) 374 68 44 Заказать звонок

Область применения

The application spectrum reaches across all industries and comprises, for example:

  • Main drives in presses and extruders
  • Converting applications
  • Rotary axes in the paper and printing industry
  • Use in crane systems

The 1PH8 motors are suitable for installation in dry indoor areas without corrosive atmospheres.

Обзор

SIMOTICS M-1PH8 motors, forced ventilation, shaft heights 80 to 160

SIMOTICS M-1PH8 motors, water cooling, shaft heights 80 to 160

SIMOTICS M-1PH8 motors, water cooling, shaft heights 180 to 280

SIMOTICS M-1PH8 motors, forced ventilation, shaft height 355

The SIMOTICS M-1PH8 motor series is a new motor generation for universal implementation in plants and machines that have been developed with Motion Control applications. The motors are available as an asynchronous variant as well as a compact synchronous variant with either forced ventilation or water cooling, based on a flexible building block principle. Comprehensive function expansions such as different bearing concepts expand the application range.

In comparison to the freely selectable performance of vector and servo control with the SINAMICS S120 drive system, it is possible to select between asynchronous or synchronous variants in the case of the 1PH8 motor series. This flexible interoperation of converter and motor makes it even easier to master extreme duty cycles, short control rise times and high precision in terms of speed, torque and positioning.

Because the 1PH8 motors are often used as the largest and central drive in the machine, they are known as "main motors".

Main motor = High performance + Highly dynamic response + High degree of protection

When developing the new 1PH8 motor series, we took special care to ensure maximum compatibility with the SINAMICS S120 drive system. For example, the specially harmonized power components, electronic rating plates, and the ability to integrate the motors via the DRIVE-CLiQ system interface ensure quick and easy commissioning as well as problem-free operation.

Характеристика

Typical speed/power characteristic for SIMOTICS M-1PH8 asynchronous motors

The characteristic curves show the typical relationship between motor speed and drive power for SIMOTICS M-1PH8 motors for duty type S1 (continuous duty) in accordance with IEC 60034-1.

The detailed characteristic curves for the corresponding voltage and winding variants can be found in the SIMOTICS M-1PH8 Configuration Manual..

Заказные данные

Скачать в формате PDF

Чертеж

Скачать в формате PDF

Особенности

  • High power density with small motor dimensions
  • Wide speed control ranges
  • High degree of flexibility due to the choice of
  • Asynchronous or synchronous design
  • Forced ventilation or water cooling
  • Mechanical designs
  • Long-life bearings
  • High rotational accuracy, even at the lowest speeds
  • Maximum thermal utilization over the complete speed range
  • Low sound pressure level
  • Optimized for the SINAMICS S120 drive system

Технические данные

SIMOTICS M-1PH8 motor forced ventilation/open-circuit cooling

Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1)

For an ambient temperature of up to 40 °C (104 °F)
Temperature class 180 (H)

Cooling in accordance with EN 60034-6 (IEC 60034-6)

  • 1PH808 ... 1PH822
  • 1PH835

Forced ventilation


Fan mounted axially at NDE

Fan mounted radially at NDE

Temperature monitoring

KTY temperature sensor in the stator winding

1PH818 ... 1PH835 additional KTY 84 as reserve

Motor fan ratings

 
  • 1PH808
  • 1PH810 ... 1PH816
  • 1PH818/1PH822
  • 1PH8828/1PH835

230 V 1 AC 50/60 Hz, 265 V 1 AC 60 Hz

400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz

200 V ... 277 V 1 AC 50/60 Hz (EC fan)

400 V 3 AC 50/60 Hz, 480 V 3 AC 60 Hz

Type of construction in accordance with EN 60034-7 (IEC 60034-7)

 
  • 1PH808
  • 1PH810 ... 1PH835

IM B3, IM B5

IM B3, IM B5, IM B35

Degree of protection in accordance with EN 60034-5 (IEC 60034-5)

 
  • 1PH808 ... 1PH835
  • 1PH818 ... 1PH835

IP55

IP23

Shaft extension on the drive end in accordance with DIN 748-3 (IEC 60034-5)

Plain shaft or feather key, full-key or half-key balancing for feather key

Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1) 1)

 
  • 1PH808 ... 1PH816
  • 1PH818 ... 1PH835

Tolerance R (reduced)

Tolerance N (normal)

Vibration severity in accordance with Siemens/EN 60034-14
(IEC 60034-14) 1)

 
  • 1PH808 ... 1PH816
  • 1PH818 ... 1PH835

Grade R/A

Grade A

Sound pressure level LpA (1 m) in accordance with DIN EN ISO 1680, max.
Tolerance +3 dB

 

Forced ventilation (IP55)

 
  • 1PH808 ... 1PH813

70 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm

  • 1PH816

73 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm

  • 1PH818

73 dB at a rated pulse frequency of 2 kHz and a speed range up to 5000 rpm

  • 1PH822

73 dB at a rated pulse frequency of 2 kHz and a speed range up to 3500 rpm

  • 1PH828

74 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm

  • 1PH835

77 dB at a rated pulse frequency of 2.5 kHz and a speed range up to 2800 rpm

Open-circuit cooling (IP23)

 
  • 1PH818

73 dB at a rated pulse frequency of 2 kHz and a speed range up to 3000 rpm

  • 1PH822

73 dB at a rated pulse frequency of 2 kHz and a speed range up to 2000 rpm

  • 1PH828

74 dB at a rated pulse frequency of 2 kHz and a speed range up to 2800 rpm

  • 1PH835

77 dB at a rated pulse frequency of 2.5 kHz and a speed range up to 2800 rpm

Built-in encoder systems without DRIVE-CLiQ interface

  • Absolute encoder EnDat 2048 S/R (encoder AM2048 S/R)
  • Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (encoder IC2048 S/R)
  • Incremental encoder sin/cos 1 Vpp 512 S/R without C and D tracks (encoder IN512 S/R)
  • Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks (encoder IN256 S/R)
  • Incremental encoder HTL 1024 S/R (encoder HTL 1024 S/R)
  • Incremental encoder HTL 2048 S/R (encoder HTL 2048 S/R)

Built-in encoder systems with DRIVE-CLiQ interface

  • Absolute encoder 22 bit single-turn + 12 bit mult-iturn (encoder AM22DQ)
  • Incremental encoder 22 bit with commutation position (encoder IC22DQ)
  • Incremental encoder 20 bit without commutation position (encoder IC20DQ)
  • Incremental encoder 19 bit without commutation position (encoder IC19DQ)

Connection

Connector for signals or DRIVE-CLiQ-interface
(mating connector not included in the scope of supply)

  • 1PH808 ... 1PH813
  • 1PH816 ... 1PH822
  • 1PH828/1PH835

Terminal box NDE top/power connector

Terminal box top

Terminal box NDE right

Rating plate

1 attached to motor

1 supplied separately with terminal box

Paint finish

Standard paint finish in anthracite RAL 7016

Approvals, according to

cURus



1) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.

S/R = signals/revolution

SIMOTICS M-1PH8 motor water cooling

Insulation of the stator winding in accordance with EN 60034-1 (IEC 60034-1)

For an cooling water inlet temperature of up to 30 °C (86 °F)
Temperature class 180 (H)2)

Cooling in accordance with EN 60034-6 (IEC 60034-6)

Water cooling
Max. cooling water pressure at inlet: 6 bar
Connecting thread at NDE

Temperature monitoring

  • 1PH808 ... 1PH816
  • 1PH818 ... 1PH828

KTY temperature sensor in the stator winding

1 additional KTY84 as reserve

Type of construction in accordance with EN 60034-7 (IEC 60034-7)

 
  • 1PH808
  • 1PH810 ... 1PH828

IM B3, IM B5

IM B3, IM B5, IM B35

Degree of protection in accordance with EN 60034-5 (IEC 60034-5)

 
  • 1PH808 ... 1PH816
  • 1PH818 ... 1PH828

IP65

IP55

Shaft extension on the drive end in accordance with DIN 748-3 (IEC 60034-5)

Plain shaft or feather key, full-key or half-key balancing for feather key

Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072-1) 1)

 
  • 1PH808 ... 1PH816
  • 1PH818 ... 1PH828

Tolerance R (reduced)

Tolerance N (normal)

Vibration severity in accordance with Siemens/EN 60034-14
(IEC 60034-14) 1)

 
  • 1PH808 ... 1PH816
  • 1PH818 ... 1PH828

Grade R/A

Grade A

Sound pressure level LpA (1 m) in accordance with DIN EN ISO 1680, max.
Tolerance +3 dB

 
  • 1PH808 ... 1PH813

68 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm

  • 1PH816

69 dB at a rated pulse frequency of 4 kHz and a speed range up to 5000 rpm

  • 1PH818

70 dB at a rated pulse frequency of 2 kHz or 4 kHz and a speed range up to 5000 rpm

  • 1PH822

70 dB at a rated pulse frequency of 2 kHz or 4 kHz and a speed range up to 4500 rpm

  • 1PH828

72 dB at a rated pulse frequency of 2 kHz and a speed range up to 3300 rpm

Built-in encoder systems without DRIVE-CLiQ interface

  • Absolute encoder EnDat 2048 S/R (encoder AM2048 S/R)
  • Incremental encoder sin/cos 1 Vpp 2048 S/R with C and D tracks (encoder IC2048 S/R)
  • Incremental encoder sin/cos 1 Vpp 512 S/R without C and D tracks (encoder IN512 S/R)
  • Incremental encoder sin/cos 1 Vpp 256 S/R without C and D tracks (encoder IN256 S/R)
  • Incremental encoder HTL 1024 S/R (encoder HTL 1024 S/R)
  • Incremental encoder HTL 2048 S/R (encoder HTL 2048 S/R)

Built-in encoder systems with DRIVE-CLiQ interface

  • Absolute encoder 22 bit single-turn + 12 bit mult-iturn (encoder AM22DQ)
  • Incremental encoder 22 bit with commutation position (encoder IC22DQ)
  • Incremental encoder 20 bit without commutation position (encoder IC20DQ)
  • Incremental encoder 19 bit without commutation position (encoder IC19DQ)

Connection

Connector for signals or DRIVE-CLiQ interface
(mating connector not included in the scope of supply)

  • 1PH808 ... 1PH813
  • 1PH816 ... 1PH828

Terminal box NDE top/power connector

Terminal box top

Paint finish

Standard paint finish in anthracite RAL 7016

Approvals, according to

cURus



1) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.

2) The following motors are designed to conform to temperature class 155 (F):1PH8107-1.F2/1PH8107-1.M21PH8138-2.F2/1PH8138-2.G21PH8164/1PH8166/1PH8168

Ventilation data/Sound pressure levels

Motor type

Fan motor current consumption, max.

Direction of air flow

Volume of air, min.

Sound pressure level
LpA (1 m)

Motor + external fan operation 50 Hz,
tolerance + 3 dB

 

A

A

A

 

m3/s (ft3/s)

dB

Forced ventilation

230 V 1 AC/50 Hz (± 10 %)

230 V 1 AC/60 Hz (± 10 %)

265 V 1 AC/60 Hz (± 10 %)

   

1PH808

0.33
0.20

0.25
0.16

0.32
0.19

NDE → DE
DE → NDE

0.02 (0.71)

70 1)

Forced ventilation

400 V 3 AC/50 Hz (± 10 %)

400 V 3 AC/60 Hz (± 10 %)

480 V 3 AC/60 Hz (± 10 %)

   

1PH810

0.12
0.13

0.09
0.09

0.12
0.13

NDE → DE
DE → NDE

0.04 (1.41)

70 1)

1PH813

0.13
0.21

0.16
0.19

0.17
0.23

NDE → DE
DE → NDE

0.09 (3.18)

70 1)

1PH816

0.17
0.23

0.22
0.30

0.22
0.30

NDE → DE
DE → NDE

0.16 (5.65)

73 1)

Forced ventilation (EC fan)

200 V ... 277 V 1 AC/50 Hz, 60 Hz (± 10 %)

1PH818

1.45 ... 1.05

NDE → DE
DE → NDE

0.17 (6.00)

73 2)

1PH822

2.3 ... 1.6

NDE → DE
DE → NDE

0.31 (10.9)

73 2)

Forced ventilation

400 V 3 AC/50 Hz (± 10 %)

400 V 3 AC/60 Hz (+ 5 %, ± 10 %)

480 V 3 AC/60 Hz (+ 5 %, – 10 %)

   

1PH828

2.55

2.5

2.5

NDE → DE
DE → NDE

0.31 (10.9)

74 2)

1PH835.-1..1 (IP55 degree of protection)

4.7

4.6

4.6

NDE → DE
DE → NDE

0.75 (26.5)

77 3)

1PH835.-1..4
(IP23 degree of protection)

4.7

4.6

4.6

NDE → DE
DE → NDE

1 (35.3)

77 3)



1) For rated pulse frequency of 4 kHz and speed range up to 5000 rpm.

2) For rated pulse frequency of 2 kHz and speed ranges:  

Forced ventilation (IP55 degree of protection):  1PH818 up to 5000 rpm  1PH822 up to 3500 rpm  1PH828 up to 3300 rpm

Forced ventilation (IP23 degree of protection): 1PH818 up to 3000 rpm 1PH822 up to 2000 rpm 1PH828 up to 2800 rpm

3) For rated pulse frequency of 2.5 kHz and speed range up to 2800 rpm.

preloader