preloader
mail@uselogic.ru  +7(495) 374 68 44 Заказать звонок

Обзор

Switch-Over Modules switch Motor Modules and motors together in accordance with their type. This results in an increase in plant availability due to redundancy and optimum utilization of the available plant components. The Switch-Over Modules can be optionally equipped with analog measuring instruments integrated into the cabinet door for indication of the output voltage of the Motor Modules and for indicating the motor currents.

Дизайн

A total of 4 circuit versions are available.

Version A

A Motor Module operates either Motor 1 or Motor 2

Function diagram for version A

Implementation of version A with option B80:
2 ammeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the motor currents and a voltmeter (analog measuring instrument of moving-coil type, 240° scale) for indicating the output voltage of the Motor Module.

Version B

Motor Module 1 operates Motor 1 and Motor Module 2 operates Motor 2 or Motor Module 1 operates Motor 2 and Motor Module 2 operates Motor 1

Function diagram for version B

Implementation of version B with option B80:
2 ammeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the motor currents and 2 voltmeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the output voltage at the Motor Modules.

Version C

Motor Module 1 operates Motor 1.1 and

Motor Module 2 operates Motor 1.2 or

Motor Module 1 operates Motor 2 or

Motor Module 2 operates Motor 2

Function diagram for version C

Implementation of version C with option B80:
3 ammeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the motor currents and 2 voltmeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the output voltage at the Motor Modules.

Version D

Motor Module 1 operates Motor 1 or 2 or 3 or 4 and

Motor Module 2 operates a motor other than Motor Module 1

Function diagram for version D

Implementation of version D with option B80:
2 ammeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the motor currents and 2 voltmeters (analog measuring instrument of moving-coil type, 240° scale) for indicating the output voltage at the Motor Modules.

The checkback contacts of the individual contactors are connected to terminals to support plant-specific interlocks.

Интеграция

The motors and Motor Modules are connected to the Switch-Over Module in accordance with the grouping.

Version A

Connection example of a Switch-Over Module, Version A

Version B

Connection example of a Switch-Over Module, Version B

Version C

Connection example of a Switch-Over Module, Version C

Version D

Connection example of a Switch-Over Module, Version D

Опции

The table below lists the options available for Switch-Over Modules (for details, refer to the section "Description of the options"):

Brief description of options

Additional identification code -Z with order code and plain text if required

Cranes industry version

B70

Measuring instruments in control cabinet door

B80

Cabinet anti-condensation heating

L55

Base 100 mm high, RAL 7022

M06

Cable compartment 200 mm high, RAL 7035

M07

IP21 degree of protection

M21

IP23 degree of protection (includes M60)

M23

Side panel (right)

M26

Side panel (left)

M27

Additional touch protection (included in M23)

M60

EMC shield bus

M70

DC busbar system (Id = 1170 A, 1 × 60 × 10 mm)

M80

DC busbar system (Id = 1500 A, 1 × 80 × 10 mm)

M81

DC busbar system (Id = 1840 A, 1 × 100 × 10 mm)

M82

DC busbar system (Id = 2150 A, 2 × 60 × 10 mm)

M83

DC busbar system (Id = 2730 A, 2 × 80 × 10 mm)

M84

DC busbar system (Id = 3320 A, 2 × 100 × 10 mm)

M85

DC busbar system (Id = 3720 A, 3 × 80 × 10 mm)

M86

DC busbar system (Id = 4480 A, 3 × 100 × 10 mm)

M87

Crane transport assembly (top-mounted)

M90

Special paint finish for cabinet

Y09 ● and special color RAL ....

Assembly into transport units at factory

Y11 ● and identification code

Label for plant identification, 1-line, 40 × 80 mm

Y31 ● and identification code

Label for plant identification, 2-line, 40 × 180 mm

Y32 ● and identification code

Label for plant identification, 4-line, 40 × 180 mm

Y33 ● and identification code

Customer documentation (circuit diagram, terminal diagram, layout diagram) in DXF format

D02



Certain options may be mutually exclusive.

Inadmissible option combinations:

  • M21 (IP21 degree of protection) and M23 (IP23 degree of protection)
  • Y31, Y32, Y33 (1, 2 or 4-line label for plant identification)
DC busbar system mechanical options (busbars between individual Cabinet Modules)
 

M80

M81

M82

M83

M84

M85

M86

M87

M80

 

M81

 

M82

 

M83

 

M84

 

M85

 

M86

 

M87

 


✓ Combination possible

– Combination not possible

Технические данные

Line voltage
380 ... 480 V 3 AC

Switch-Over Module

 

Type

 

6SL3700‑2FE36-1AA3‑Z
B70

6SL3700‑2FE36-1BA3‑Z
B70

6SL3700‑2FE36-1CA3‑Z
B70

6SL3700‑2FE36-1DA3‑Z
B70

Version

 

A

B

C

D

Number of contactors

 

2

4

4

8

Rated current

A

605

605

605

605

Power loss

kW

< 1

< 1

< 1

< 1

Cooling air requirement

 

Convection

Convection

Convection

Convection

Sound pressure level LpA

dB

Line supply/load connection

 

6 × M12

6 × M12

6 × M12

6 × M12

Cable length, max.

     
  • Shielded

m

300

300

300

300

  • Unshielded

m

450

450

450

450

PE connection

 

PE bar 600
8 × M12

PE bar 600
8 × M12

PE bar 600
8 × M12

PE bar 600
8 × M12

Degree of protection

 

IP20

IP20

IP20

IP20

Dimensions

     
  • Width

mm

600

600

600

600

  • Height

mm

2200

2200

2200

2200

  • Depth

mm

600

600

600

600

Weight, approx.

kg

320

360

380

430

Matching Motor Modules

 

6SL3720‑1TE35‑0AA3

6SL3720‑1TE35‑0AA3

6SL3720‑1TE35‑0AA3

6SL3720‑1TE35‑0AA3

 

6SL3720‑1TE36‑1AA3

6SL3720‑1TE36‑1AA3

6SL3720‑1TE36‑1AA3

6SL3720‑1TE36‑1AA3



Line voltage
380 ... 480 V 3 AC

Switch-Over Module

 

Type

 

6SL3700‑2FE39-9AA3‑Z
B70

6SL3700‑2FE39-9BA3‑Z
B70

6SL3700‑2FE39-9CA3‑Z
B70

Version

 

A

B

C

Number of contactors

 

4

8

8

Rated current

A

985

985

985

Power loss

kW

< 1

< 2

< 2

Cooling air requirement

 

Convection

Convection

Convection

Sound pressure level LpA

dB

Line supply/load connection

 

10 × M12

10 × M12

10 × M12

Cable length, max.

    
  • Shielded

m

300

300

300

  • Unshielded

m

450

450

450

PE connection

 

PE bar 600
8 × M12

PE bar 800
10 × M12

PE bar 800
10 × M12

Degree of protection

 

IP20

IP20

IP20

Dimensions

    
  • Width

mm

600

800

800

  • Height

mm

2200

2200

2200

  • Depth

mm

600

600

600

Weight, approx.

kg

400

600

650

Matching Motor Modules

 

6SL3720‑1TE37‑5AA3

6SL3720‑1TE37‑5AA3

6SL3720‑1TE37‑5AA3

 

6SL3720‑1TE38‑4AA3

6SL3720‑1TE38‑4AA3

6SL3720‑1TE38‑4AA3

 

6SL3720‑1TE41‑0AA3

6SL3720‑1TE41‑0AA3

6SL3720‑1TE41‑0AA3



Line voltage
380 ... 480 V 3 AC

Switch-Over Module

 

Type

 

6SL3700‑2FE41-3AA3‑Z
B70

6SL3700‑2FE41-3BA3‑Z
B70

6SL3700‑2FE41-3CA3‑Z
B70

Version

 

A

B

C

Number of contactors

 

6

8

8

Rated current

A

1260

1260

1260

Power loss

kW

< 1.5

< 2

< 2

Cooling air requirement

 

Convection

Convection

Convection

Sound pressure level LpA

dB

Line supply/load connection

 

14 × M12

14 × M12

14 × M12

Cable length, max.

    
  • Shielded

m

300

300

300

  • Unshielded

m

450

450

450

PE connection

 

PE bar 800
10 × M12

PE bar 800
10 × M12

PE bar 800
10 × M12

Degree of protection

 

IP20

IP20

IP20

Dimensions

    
  • Width

mm

800

800

800

  • Height

mm

2200

2200

2200

  • Depth

mm

600

600

600

Weight, approx.

kg

550

650

750

Matching Motor Modules

 

6SL3720‑1TE41‑2AA3

6SL3720‑1TE41‑2AA3

6SL3720‑1TE41‑2AA3



Line voltage
380 ... 480 V 3 AC

Switch-Over Module

 

Type

 

6SL3700‑2FE41-4AA3‑Z
B70

6SL3700‑2FE41-4BA3‑Z
B70

6SL3700‑2FE41-4CA3‑Z
B70

Version

 

A

B

C

Number of contactors

 

6

12

12

Rated current

A

1405

1405

1405

Power loss

kW

< 1.5

< 2.5

< 2.5

Cooling air requirement

 

Convection

Convection

Convection

Sound pressure level LpA

dB

Line supply/load connection

 

14 × M12

14 × M12

14 × M12

Cable length, max.

    
  • Shielded

m

300

300

300

  • Unshielded

m

450

450

450

PE connection

 

PE bar 800
10 × M12

PE bar 1200
10 × M12

PE bar 1200
10 × M12

Degree of protection

 

IP20

IP20

IP20

Dimensions

    
  • Width

mm

800

1200

1200

  • Height

mm

2200

2200

2200

  • Depth

mm

600

600

600

Weight, approx.

kg

550

800

850

Matching Motor Modules

 

6SL3720‑1TE41‑4AA3

6SL3720‑1TE41‑4AA3

6SL3720‑4TE41‑2AA3



Дальнейшая информация

For further information about Swirch-Over Modules and for ordering information, see Catalog CR 1 · 2012.

The catalog can be found at http://www.siemens.com/cranes

→ Catalog & ordering system online → Show Catalog/order.

preloader

55928